Field Installed Female NPT Header Fitting — Product Overview
The Series 799 header fitting puts a female NPT tap straight onto the wall of HDPE pipe. A barbed metal fitting is hydraulically pressed into a polyethylene coupling, and the coupling is socket-fused to the outside of the main through a drilled hole. The result is a low-profile threaded outlet for probes, meters, gauges and small service connections, with no long arm sticking out of the pipe. It can also be installed in HDPE caps, blind flanges, tees and elbows.
Ordering: Request a quote with the NPT size, the metal you need (304 stainless, 316 stainless, aluminum bronze or brass) and the main pipe size and DR. We will confirm part number, price and lead time.
Features
- Low profile: Probes and meters go in without a longer arm or a saddle tee.
- Full pressure rating: Designed to the pressure rating of the HDPE pipe with a 2:1 safety factor at 73.4°F and a 50-year minimum design life.
- Standard threads: .5" to 2" female NPT, threads made to ANSI/ASME B1.20.1-2013.
- Metal options: Type 304 or Type 316 stainless steel (ASTM A249 / A269), C954 aluminum bronze (lead free, complies with California AB1953, SB1334 and SB1935) or C360 brass.
- HDPE coupling: PE3408, PE3608 or PE4710 material, cell class 345454C, or pipe quality copolymer.
- Made in the USA: Manufactured to ASTM D3035, D1598, D1599 and D3350, and meets ARRA requirements. Certifications are available on request.
Specifications
| NPT Size | Coupling Nominal I.D. (A) | Coupling Height (B) |
|---|---|---|
| .5" | .84" | 2.15" |
| .75" | 1.05" | 2.65" |
| 1" | 1.315" | 2.5" |
| 1.25" | 1.66" | 2.5" |
| 1.5" | 1.9" | 2.5" |
| 2" | 2.375" | 3" |
Installation
- Fusion: Hand socket fusion by a trained operator using Series 400 male and Series 401 female heater faces and the Series 402 hand tool. Hand fusion works on main pipe 2" to 63"; saddle fusion machines can be used on main pipe 2" to 12".
- Install with: Series 400-402 socket fusion plates and installation hand tool LINK
- Threads: Use pipe joint sealant or PTFE tape. Use strap wrenches, two at a time, never a pipe wrench. Over-tightening can cause ovality or damage.
- Before backfill: Pressure test for leaks, then backfill and compact carefully around the fitting and service line.
- Warranty: One year from substantial completion of installation.