PRIME CONDUIT  |  SKU: 30055252  |  MPN: CPSPLT1S200X600

Split Sleeve Couplings | Sch 40 and 80 Split Repair Coupling

$2,004.26
Sold in case qty's of 25. Request a quote for current pricing & lead times.
Size x Length | Split
Lead Time: Made to order - manufacturing lead time applies.
  • Split Sleeve Coupling: Opens around installed cable and closes over the joint, no cable removal.
  • Fits Sch 40 and Sch 80: Same outside diameter, one coupling for both schedules.
  • One-Side or Two-Side Split: 2" to 6", for joining split duct to existing conduit and repairing damaged runs.
  • Sold by the Case: Made to order, manufacturing lead time applies. Call (815) 337-8845 or request a quote.
  • View Split Duct Here > LINK

Split Sleeve Couplings — Schedule 40 PVC repair couplings split lengthwise, for joining split duct and repairing conduit around installed cable.

A split sleeve coupling is a standard PVC coupling with the wall split along its length so it can open around an installed cable and close over a joint. The sleeve is open-ended and slides to wherever the joint sits. It is the coupling Prime specifies for joining Split Duct to existing conduit, and it works the same way on a repair where a damaged section has been cut out. Schedule 40 and Schedule 80 conduit share the same outside diameter, so one coupling fits both.

One-Side or Two-Side Split

  • One-side split (CPSPLT1S): a single cut along the sleeve. The sleeve springs open enough to pass over a cable and closes back to round. The standard choice.
  • Two-side split (CPSPLT2S): cut into two halves. Easier to fit around a large or stiff cable bundle, or where there is no room to spring a one-piece sleeve open.

Key Features

  • No cable removal: installs around existing conductors
  • Fits Sch 40 and Sch 80: same outside diameter, one coupling for both
  • Schedule 40 PVC: solvent cementable, UV resistant, for direct burial and encased duct
  • Sold by the case: case quantities in the table; made to order, manufacturing lead time applies
  • Pricing: quoted per order. Call (815) 337-8845 or use the quote button with the size and quantity you need

Before You Order

  • Split duct butts up to the existing conduit; the split coupling goes over the outside of the joint. Order the coupling to the conduit trade size.
  • Not a listed product. Like split duct, split sleeve couplings carry no ETL or UL listing. Where the NEC governs, confirm acceptance with the authority having jurisdiction before you order.
  • Joining solid conduit with a centered stop? That is a standard long line coupler. View Sch 40 Long Line Couplers Here > LINK

Order Guide

Part Number Size x Length Split UPC Case Qty
CPSPLT1S200X600 2" x 6" 1-side 670648000351 25
CPSPLT2S200X600 2" x 6" 2-side 670648024999 25
CPSPLT1S250X700 2-1/2" x 7" 1-side 670648000368 25
CPSPLT2S250X700 2-1/2" x 7" 2-side 670648159486 25
CPSPLT1S300X700 3" x 7" 1-side 670648000375 25
CPSPLT2S300X650 3" x 6-1/2" 2-side 670648000481 25
CPSPLT1S350X800 3-1/2" x 8" 1-side 670648000511 25
CPSPLT1S400X800 4" x 8" 1-side 670648000399 15
CPSPLT2S400X600 4" x 6" 2-side 670648000993 25
CPSPLT1S500X400 5" x 4" 1-side 670648000443 30
CPSPLT1S500X800 5" x 8" 1-side 670648000450 15
CPSPLT1S500X900 5" x 9" 1-side 670648000467 8
CPSPLT1S600X1000 6" x 10" 1-side 670648000474 4

Size is nominal conduit size x coupling length; the coupling fits Schedule 40 and Schedule 80 conduit of that size. Sold in full manufacturer cases; the case quantity is the minimum order and the order increment. Blue rows are two-side split. Ships from the manufacturer.

Complete the Repair

  • Split duct, 10-foot split conduit sections. View Split Duct Here > LINK
  • Split duct couplers for joining split duct sections to each other. View Split Duct Couplers Here > LINK
  • Split kits, a 2-foot split section with two split couplings for a short repair. View Sch 40 Split Kits Here > LINK
  • Type C telephone duct split sleeves for 4" C-duct. View C-Duct Split Sleeves Here > LINK