PRIME CONDUIT  |  SKU: 30055047  |  MPN: 49005-010

Schedule 40 PVC Conduit | Rigid Nonmetallic | Bell End | 10' & 20' Sticks

$0.38
Sold in 6,000 ft bundles | Request quote for pricing & lead time
Size
Length
Lead Time: Made to order - manufacturing lead time applies.
  • Schedule 40 PVC Conduit: Heavy wall rigid nonmetallic conduit, 1/2" to 6", 10 and 20 ft bell end sticks.
  • Listed for NEC 352 Work: ETL listed to UL 651, NEMA TC-2; underground, encased or exposed.
  • Solvent Weld Bell End: One integral bell per stick; use RNC fittings and PVC cement.
  • Stocked Sizes Ship From Woodstock IL: Sold by the foot, partial bundles available; other sizes ship from the manufacturer in full bundles.
  • Quoted Per Order: Call (815) 337-8845 or use the quote request.

Schedule 40 PVC Conduit, Bell End — heavy wall rigid nonmetallic conduit for underground and aboveground electrical raceway, in 10 and 20 ft sticks, 1/2" through 6".

Schedule 40 is the general-purpose rigid PVC conduit: ETL listed to UL 651 and manufactured to NEMA TC-2, so it can be installed underground, encased in concrete, or exposed aboveground under NEC Article 352. It is a quarter the weight of steel, non-conductive, will not rust, and joins by solvent weld through the integral bell on each stick. Rated for 90°C conductors and sunlight resistant. For areas subject to physical damage the code calls for Schedule 80; for utility duct banks that do not need a UL listing, the lower-cost Schedule 40 Utility grade covers the same sizes.

Which Schedule 40 Do I Need?

Product Listing Typical Use
Schedule 40 (this listing) ETL listed to UL 651, NEMA TC-2 NEC 352 raceway, above or below ground, inspected work
Schedule 40 Utility NEMA TC-2 utility grade, not UL listed utility duct banks, direct burial and encasement
Schedule 80 ETL listed to UL 651, extra heavy wall areas subject to physical damage, NEC 352.12(C)

Key Features

  • Heavy wall EPC: ETL listed to UL 651, manufactured to NEMA TC-2 and Federal Spec W-C-1094A, for installation under NEC Article 352
  • Underground and aboveground: listed for direct burial, concrete encasement, and exposed or concealed use; sunlight resistant
  • Integral bell end: one bell per stick for solvent-weld joining, bell dimensions per UL 651
  • 90°C conductor rated: maximum ambient 122°F (50°C); see NEC Table 352.30(B) for support spacing
  • Sold by the foot: stocked sizes ship from Woodstock IL and can be bought in partial bundles; other sizes ship from the manufacturer in full bundles
  • Solvent weld: PVC conduit cement and primer; use RNC fittings such as the standard coupling
  • Made in the USA

Specifications

Size Part No. 10' Part No. 20' Bundle 10' (ft) Bundle 20' (ft) Wt per 100 ft (lb) Avg. O.D. (in) Min. Wall (in)
1/2" 49005-010 - 6,000 - 17 0.840 0.109
3/4" 49007-010 49007-020 4,400 8,800 23 1.050 0.113
1" 49008-010 49008-020 3,600 7,200 34 1.315 0.133
1-1/4" 49009-010 49009-020 3,300 6,600 46 1.660 0.140
1-1/2" 49010-010 49010-020 2,250 4,500 55 1.900 0.145
2" 49011-010 49011-020 1,400 2,800 73 2.375 0.154
2-1/2" 49012-010 49012-020 930 1,860 124 2.875 0.203
3" 49013-010 49013-020 880 1,760 163 3.500 0.216
3-1/2" 49014-010 49014-020 630 1,260 196 4.000 0.226
4" 49015-010 49015-020 570 1,140 232 4.500 0.237
5" 49016-010 49016-020 380 760 315 5.563 0.258
6" 49017-010 49017-020 260 520 409 6.625 0.280

Values per the Prime Conduit Schedule 40 and 80 catalog. 1/2" is supplied in 10 ft only. One belled end per stick. Prime reserves the right to ship to the nearest bundle quantity.